> R2 integration note: this is the historical pre-contact facade study. The earlier 0.256m / 0.833m contact figures are superseded by actual displayed-triangle measurements: 0.503m gap and 0.538m burial. R2 adds only separate illustrative infill in the positive gap; original body/terrain and buried regions remain unchanged. See ../contact117 and the top-level README.

# Sources and bounded assumptions

Accessed 2026-11-08. This is a 117-only facade depth pilot within the previously audited 18-building complex.

1. Numbered 117 exterior image, Zigbang CDN, discovered through public image search for the Hogangnono Yeonsu Jugong1 page:
https://s3-ap-northeast-1.amazonaws.com/zigbang/BigData/3433/b6d5a003362db8839af1329fbb667b007e620138.jpg
https://hogangnono.com/apt/72b41
The full page returned403 to the research fetch; the publicly indexed image itself was readable. No access restriction was bypassed. Number117 is directly visible. EXIF datetime2016-10-26, GPS rounded to whole seconds and not adequate for an exact camera match. Photo proves the shown building's appearance at an uncertain historical date, not its current appearance. End-wall relief, smaller window next to the near balcony, front and west-return glazing, guardrails and shallow eave underside are visible. Hidden opposite returns, back walls, roof pitch and dimensions are not established.

2. Complex-level comparison image from KB:
https://file.kbland.kr/image/kbstar/land/img/revw/userseq/997191/20220223/2c92ead4069cfc68.jpeg
https://kbland.kr/se/c/11770
The20220223 path is a file date clue, not a verified capture date. Supports cream/pink concrete, glazing and railing character at complex level. No per-dong identity claim from this image.

3. Footprint and identity retained:
https://www.openstreetmap.org/way/1200790978
https://aptsonpoom.com/danji/A38076521
https://m.richgo.ai/realty/danji/a3dSrxB
The existing eighteen-building audit supplies its exact OSM ring, source-checked5-floor record and assumed14.4m envelope. Original geometric ground is retained. No new geographic adjustment. Five south projecting segments exist in the source ring; they are not a newly guessed count.

Assumptions relative to the already assumed floor interval F=H/5:
- South-glass recess0.11F; visible west-return recess0.065F; small-window recess0.07F.
- Front opening occupies the interval0.105F–0.91F within each tier, leaving real slab/beam margins.
- Guardrail height approximately0.33F above sill; spacing approximately0.085F.
- Window frame widths approximately0.018F. Glazing is opaque, rough reflective material, not a model of interiors.
- End-wall groove depth0.009F. Two patterned fields are visually guided; frequency is approximate, not an exact count or construction profile.
- Eave undercut depth0.045F, confined to the top0.07F–0.04F. The roof top and outer silhouette do not move. Flat roof enclosure remains unresolved.
- Source-blue/teal roof material is retained. Body materials are photo-guided estimates, not calibrated colors.

No measured metre accuracy, full-building as-built certification, structural-engineering certification, present-condition guarantee or citywide completion claim. Before/after camera pair is exact; no photo/render pose-match claim.

Copyrighted source photos are internal reference only and excluded from public delivery. Own renders contain no source-photo textures. OpenStreetMap and base-model data attribution remain required.

Historical paint identity: generated117 lettering and a narrow salmon strip are mapped onto the real west wall. Approximate placement, size and color from visual observation of the2016 photograph. No photo pixels are reused. See make_endwall_paint.py and PAINT_EXPORT_QA.json. The packed image/UV is required for downstream export.

Inherited ground contact is unresolved: vertical model-to-model perimeter sampling finds gaps up to0.256m and burial up to0.833m against the existing coarse terrain/road context. Base elevation and terrain are intentionally unchanged. This is not a surveyed real-world clearance.